2013年8月19日星期一

LED strip lamp installation instructions


LED strip lamp installation instructions-Malio Lighting

First, the main structure and scope

LED light bar 6063 aluminum shade is made of high thermal conductivity, the appearance of high-grade fine, light use of U.S. imports Bridgelux chip 5050 SMD LED. For jewelry, display counters, home villa lighting, shopping malls, hotels, office buildings leisure venues decorative lighting and other lighting places, is ideal to replace the traditional fluorescent tube lighting.

Second, the structural parameters

Input voltage: 220V
Operating voltage: 12V
Power: 13.2W
Strip Length: 1m
Output flux: 1040lm
CRI: 85
Light Source: LED0.2W * 66pcs / m
Color temperature :2700-7500K
Exterior Color: Silver
Working temperature: -20 ℃ ~ +60 ℃
Operating Humidity :10-90RH
Electric shock rating: Ⅱ class
Used drive: constant current driver, stable performance, safe and reliable
Photometric Type: 120 °
Light Distribution: selected light source, the LED light color better, centralized spot uniformity, no noise, no shadows dark areas
Connection: Terminal Links

Three steps

1. Check lampshade, light bar, complete with a variety of finishing parts and accessories are complete;
2. According to the length of the counter, the processing of the shade that matches the length of the intercept, and then both ends are 45 ° chamfer
3. in the front left and right ends of the inner lamp with diameter of 3.5mm, respectively, through-holes for connecting and fixing the pad;
4. In the lower part of the left and right ends light trough distinguished two M3 holes for and triangular block connections;
5. The shade to be installed into the appropriate size light bar, connected together by means of triangular pieces;
6. The fixed block with shadowless adhesive shade in the corresponding openings around the inside of the glass;
7. Screw the connection good shade fixed on the counter;
8. fitted over the mast;
9. Install the driver. Mind when installing input and output ports, connected lights when the attention of the positive and negative connections. Red for positive connections and black for the negative connection.

IV Notes

1. LED driver is properly installed and LED lights;
2. 12V 3.2A drive connected to my company LED strip can not exceed 4m, 12V 5A driver pick me company LED light bar can not exceed 5m;
3. must cut off the power before installation operations;
4. product must be installed by professional installation.